Application areas:
– Warehouses
– Big shops
– Stack storages
– Logistics
Warehouse type sprinkler, includes 4 models.
– ESFR (Early Suppression Fast Response) Sprinkler
– CMSA (Control Mode Specific Application) Sprinkler
– CMDA (Control Mode Density Area) Sprinkler
– EC Storage (Extended Coverage) Sprinkler
ESFR (Early Suppression Fast Response) Sprinkler
ESFR has 3 different with other sprinklers
- Speed – ESFR sprinklers, heat detect and being active time nearly equal half of the other sprinklers.
- Volume – Other sprinklers throw 25-60gpm water, otherwise ESFR sprinklers throw 100gpm water.
- Water drop dimension – ESFR sprinkles has bigger water drops and flows than the other sprinklers.
ESFR – K:14 (200)
Pendent
Connection diameter: ¾”npt
Assemble type: Pendent (Pendent) Tip
K-Factor: 14 (200)
Approvals: FM, UL, ULC, LPCB, VdS
Temperature: 74°C, 96°C
Surface: Brass
Sin: VK500
– ESFR (Early Suppression, Fast Response) in fire fighting mode
– With solder it strong against the heat.
– Design for the shelf systems protect.
– Suitable for using in shelf systems.
Upright
Connection diameter: ¾”npt
Assemble Type: Upright Type
K-Factor: 14 (200)
Approvals: FM, UL, ULC, LPCB, VdS
Temperature: 74°C, 96°C
Surface: Brass
Sin: VK520
– ESFR (Early Suppression, Fast Response) in fire fighting mode
– With solder it strong against the heat.
– Design for the shelf systems protect.
– Suitable for using in shelf systems.
– Solution for the instead of the pendent sprinkler connections.
ESFR – K:17 (242) Pendent
Connection diameter: ¾”npt
Assemble type: Pendent type
K-Factor: 16.8 (242)
Approvals: FM, UL, ULC, LPCB, VdS
Temperature: 74°C, 96°C
Surface: Brass
Sin: VK503
– ESFR (Early Suppression, Fast Response) in fire fighting mode
– With solder it strong against the heat.
– Design for the shelf systems protect.
– Suitable for using in shelf systems.
– Instead of the ESFR K: 14 it needs low pressure than this sprinklers
ESFR – K:22.4 (320) Pendent
Connection Diameter: 1”npt
Assemble type: Pendent type
K-Factor: 22.4 (320)
Approvals: FM, UL, ULC, LPCB, VdS
Temperature: 74°C, 96°C
Surface: Brass
Sin: VK506
– ESFR (Early Suppression, Fast Response) in fire extinction mode.
– With solder it strong against the heat.
– Design for the shelf systems protect.
– Suitable for using in shelf systems.
– Instead of ESFR K: 17, it needs low pressure
ESFR – K:25 (363) Pendent
Connection diameter: 1”npt
Assemble type: Pendent type
K-Factor: 25 (363)
Approvals: FM, UL, ULC, LPCB, VdS
Temperature: 74°C, 96°C
Surface: Brass
Sin: VK510
– ESFR (Early Suppression, Fast Response) in fire extinction mode.
– With solder it strong against the heat.
– Design for the shelf systems protect.
– Suitable for using in shelf systems.
– Instead of ESFR K: 22, it needs low pressure
CMSA (Control Mode Specific Application) Sprinkler
HIGH CHALLENGE® LARGE DROP UPRIGHT SPRINKLER K:11.2 (160)
Connection dia: ½”npt – ¾”npt
Assemble type: Upright type
K-Factor: 11.2 (160)
Approvals: FM, UL, ULC
Temperature: 68°C, 93°C, 141°C
Surface: Brass
Sin: VK540
– With 5 mm bulb glass it is strong against heat.
– It design for until High Challenge Large Drop Sprinkler group A plastic fires extinction. For 7,6 meter height and 9,1 meter height it protect the shelf systems without any extra sprinklers.
– Between deflector and pallet of the top of the shelf have to be most least 914 mm.
STANDARD RESPONSE CMSA PENDENT SPRINKLER K:19.6 (282.6)
Connection diameter: 1”npt
Assemble: Pendent type
K-Factor: 19.6 (282.6)
Approvals: FM, UL, ULC
Temperature: 71°C, 96°C
Surface: Brass
Sin: VK592
– With solder, it strong against the heat.
– It design for until Standart Response CMSA Pendent Sprinkler group A plastic fires extinction. For 7,6 meter height and 9,1 meter height it protect the shelf systems without any extra sprinklers.
– Between deflector and pallet of the top of the shelf have to be most least 914 mm.
CMDA (Control Mode Density Area) Sprinkler
UPRIGHT SPRINKLER (STORAGE-DENSITY/AREA) K:16.8 (242)
Connection Diameter: ¾”npt
Assemble type: Upright type
K-Factor: 16.8 (242)
Approvals: FM, UL, ULC
Temperature: 68°C, 79°C, 93°C, 141°C
Surface: Brass
Sin: VK580
– With 5 mm bulb glass it is strong against heat.
– For needs low pressure, it makes low pipe line, lower pumps and it make some cost savings.
– Design for the high height storage systems
– Standard response sprinkler system.
ELO sr UPRIGHT/pendent SPRINKLER (STORAGE-DENSITY/AREA) K:11.2 (160)
Connection Type: ¾”npt
Assemble type: Upright / Pendent Type
K-Factor: 11.2 (160)
Approvals: FM, UL, ULC
Temperature: 68°C, 79°C, 93°C, 141°C
Surface: Brass, Chromed, Black and White
Sin: VK530 / VK536
– With 5 mm bulb glass it is strong against heat.
– Standard response sprinklers.
– With extra big orifice, design for the high capacitive storages and the manufacturers.
– For needs low pressure, it makes low pipe line, lower pumps and it make some cost savings
– If it use with the sprinkler cover case, it will be act like an intermediate level sprinklers.
ELO qr UPRIGHT/pendent SPRINKLER (STORAGE-DENSITY/AREA) K:11.2 (160)
Connection Type: ¾”npt
Assemble type: Upright / Pendent Type
K-Factor: 11.2 (160)
Approvals: FM, UL, ULC
Temperature: 68°C, 79°C, 93°C, 141°C
Surface: Brass, chromed, Black and White
Sin: VK531-533 / VK377
– With 3 mm bulb glass and, solder it strong against for the heat.
– Quick response sprinklers
– With extra big orifice, design for the high capacitive storages and the manufacturers.
– For needs low pressure, it makes low pipe line, lower pumps and it make some cost savings
– If it use with the sprinkler cover case, it will be act like a intermediate level sprinklers.
EC Storage (Extended Coverage) Sprinkler
EXTENDED COVERAGE UPRIGHT SPRINKLER (STORAGE-DENSITY/AREA) K:25.2 (363)
Connection Type: ½”npt
Assemble Type: Upright Type
K-Factor: 25.2 (363)
Approvals: FM, UL, ULC
Temperature: 74°C, 101°C
Surface: Brass
Sin: VK595
– With the solder, it strong against heat.
– Design for the high risky warehouses and productions.
– Between deflector and pallet of the top of the shelf have to be most least 914 mm.
Read More: Sprinkler