Features Pressure transmitter Model SXSA
- Intrinsically safe pressure transmitter,
- For food industry and sanitary applications,
- ATEX version,
- Accuracy 0,5%
Specification Pressure transmitter Model SXSA
- Ignition protection Ex ia as per EN 60079-0, EN 60079-11, EN
60079-26, atmosphere type GD :- category 1, marking II 1 GD Ex ia IIC Ex ia IIIC (cod. 1GD);
- category 1/2, marking II 1/2 GD Ex ia IIC Ex ia IIIC (cod. 2GD).
- Temperature classes
- T6 (T85°C)Ta ≤ 60 °C (cod. T6B);
- T5 (T100°C)Ta ≤ 80 °C (cod. T5B);
- T4 (T135°C)Ta ≤ 100 °C (cod. T4B).
- Measuring ranges: 0…0,6/0…40 bar, relative; -1…0/-1…+24 bar, relative; 0…0,6/0…16 bar, absolute.
- Output signal: 4…20 mA (cod. 1).
- Non-linearity (BFSL): ≤ ± 0,25 % of the range, according to IEC 61298-2.
- Non-repeatability: ≤ 0,15 % of the range, according to IEC 61298-2.
- Accuracy: ≤ ± 0,5% of the range (3).
- Long term drift: ≤ 0,2 % of span.
- Zero and span adjustement: ± 10 % span typical.
- Stocking temperature: -10…+85 °C.
- Response time: <4 ms (measuring); <150 ms (switching on).
- Emission and immunity: according to EN 61326 (group 1 – class B; industrial applications).
- Vibration resistance: 20g (10…2000 Hz, according to IEC 60068-2-6).
- Shock resistance: 40g (6 ms, according to IEC 60068-2-27).
- Sensor: ceramic in Al2O3 or piezoresistive.
- Seal fill: oil for food service (FDA).
- Case: in AISI 316L, vented up to 16 bar.
- Protection degree: IP 65 according to IEC 60529 (4).
- Diaphragm and process connection: in AISI 316L.
Read More: Pressure transmitter