Features Pressure transmitter Model SX09
- Intrinsically safe pressure transmitter,
- ATEX version,
- Accuracy 0,35%
Specification Pressure transmitter Model SX09
- Ignition protection Ex ia as per EN 60079-0, EN 60079-11, EN 60079-26, atmosphere type GD:
- category 1 (1), marking II 1 GD Ex ia IIC Ex ia IIIC (cod. 1GD);
- category 1/2, marking II 1/2 GD Ex ia IIC Ex ia IIIC (cod. 2GD).
- Temperature classes
- T6 (T85°C)Ta ≤ 60 °C (cod. T6B);
- T5 (T100°C)Ta ≤ 80 °C (cod. T5B);
- T4 (T135°C)Ta ≤ 100 °C (cod. T4B).
- Measuring ranges: 0…1/0…1000 bar, relative; -1…0/-1…+24 bar, relative; 0…1/0..25 bar, absolute.
- Output signal: 4…20 mA (cod. 1).
- Non-linearity (BFSL): ≤ ± 0,175 % of the range, according to IEC 61298-2.
- Non-repeatability: ≤ 0,1 % of the range, according to IEC 61298-2.
- Accuracy: ≤ ± 0,35% of the range (3).
- Thermal drift: between 0 and 80°C, 1% of span; 2,5% of span, max (4).
- Long term drift: ≤ 0,1 % of span.
- Zero and span adjustement: ± 10 % span typical.
- Stocking temperature: -30…+85 °C.
- Response time: <4 ms (measuring); <150 ms (switching on).
- Emission and immunity: according to EN 61326, (group 1 – class B; industrial applications).
- Vibration resistance: 20g (10…2000 Hz, according to IEC 60068-2-6).
- Shock resistance: 40g (6 ms, according to IEC 60068-2-27).
- Sensor: piezoresistive, with silicon oil.
- Case: in AISI 316L, vented up to 16 bar.
- Protection degree: IP 65 according to IEC 60529 (5).
- Process connection: in AISI 316L, hole ø 2,5 mm (with restrictor ø 0,7 mm for measuring ranges ≥ 60 bar).
- Weight: 0,25 kg
Read More: Pressure transmitter