Specification Pressure Transmitter Flush Diaphragm SXMA
- Ignition protection Ex ia as per EN 60079-0, EN 60079-11, EN 60079-26, atmosphere type GD :
- – category 1, marking II 1 GD Ex ia IIC Ex ia IIIC (cod. 1GD);
- – category 1/2, marking II 1/2 GD Ex ia IIC Ex ia IIIC (cod. 2GD).
- Temperature classes
- -T6 (T85°C)Ta ≤ 60 °C (cod. T6B);
- -T5 (T100°C)Ta ≤ 80 °C (cod. T5B);
- -T4 (T135°C)Ta ≤ 100 °C (cod. T4B).
- Measuring ranges: 0…1/0…600 bar, relative.
- Output signal: 4…20 mA (cod. 1).
- Non-linearity (BFSL): ≤ ± 0,25 % of the range, according to IEC 61298-2.
- Non-repeatability: ≤ 0,15 % of the range, according to IEC 61298-2.
- Accuracy: ≤ ± 0,5% of the range.
- Long term drift: ≤ 0,2 % of span.
- Zero and span adjustement: ± 10 % span typical.
- Stocking temperature: -30…+85 °C.
- Response time: <4 ms (measuring); <150 ms (switching on).
- Emission and immunity: according to EN 61326, (group 1 – class B; industrial applications).
- Vibration resistance: 20g (10…2000 Hz, according to IEC 60068-2-6).
- Shock resistance: 40g (6 ms, according to IEC 60068-2-27).
- Sensor: ceramic in Al2O3.
- Case: in AISI 316L, vented up to 16 bar.
- Protection degree: IP 65 according to IEC 60529.
- Diaphragm and process connection: in AISI 316L.
- Weight: 0,28 kg
Read More: Pressure transmitter